NORTHERN LIGHTS 5-20 KW HEAT EXCHANGERS

Northern Lights M753 Generator

Northern Lights M753 GeneratorI was helping a customer the other day who requested a heat exchanger tube stack for an M753K.  This is a 10 year old generator, but I was still shocked that he needed a heat exchanger.  In our experience, the only thing that can cause a heat exchanger tube stack failure on a 5-20 kw generator is very poor maintenance.  When I looked up the part number for the tube stack I noticed that we had sold 3 in the last 12 months.

There are, conservatively 300-400 of these generators in operation in the Caribbean, so that works out to less than a 0.75% failure rate.  Most of our competitors would be envious of such a low failure rate, but we still feel that is too high.  The only reason that these tube stacks are failing is because of poor maintenance practices, or using the wrong coolant.

We wish to emphasize that the only proper coolant is Distilled Water, or a 50/50 premix ethylene glycol mix.  If operators wish to use 100% ethylene glycol, they need to dilute it with 50% Distilled Water.  Most of the water we get in the Caribbean comes from Reverse Osmosis, and that often leaves too high a mineral (including salt) content.  Even with proper coolant, sludge, scale and corrosion build up over a period of time.  So we recommend that our customers drain, flush and refill their cooling system every year as part of their annual maintenance.

If customers wish to extend the coolant change interval, we recommend purchasing a pack of coolant test strips (part number 20-00005) and testing coolant every 6 months past the 1 year anniversary of the last coolant change.

In addition to the tube stack failing, poor coolant quality can cause water pump failure, and the core plugs (water jackets) to corrode from the inside out.  Made of a thinner, less corrosion resistant material, the core plugs can often be the “canary in the coal mine”.  If they start to leak, the operator knows he has a problem.  A bigger problem is that some of these core plugs can be very hard to get to in order to change them.

In summary, it is a very good investment to change your coolant every year – your local dealer can take care of this for you.  It can save a lot of money down the road.

Advertisements

Tags: , , ,

About partsandpower

Parts & Power is the premier supplier of Marine and Industrial equipment and spare parts in the Caribbean.

Leave a Reply

Fill in your details below or click an icon to log in:

WordPress.com Logo

You are commenting using your WordPress.com account. Log Out / Change )

Twitter picture

You are commenting using your Twitter account. Log Out / Change )

Facebook photo

You are commenting using your Facebook account. Log Out / Change )

Google+ photo

You are commenting using your Google+ account. Log Out / Change )

Connecting to %s

%d bloggers like this: